140-CM TUBING-SWITCHED HOURLY URINE OUTPUT MONITORING DEVICE

Reference : COLDIUSWING140

  • Hourly urine output measurement with a flip-top design
  • Dual-scale volumetric scale for large and small volumes
  • Measuring system with 400 ml capacity
  • 1-ml precision up to 50 ml
  • 2,000-ml collection bag
  • Reinforced tubing
  • Needle-free sampling system with a flat surface
  • Drip chamber with integrated check valve
  • 110 cm tubing
  • Integrated hook
  • DEHP < 0.1% w/w

Description

The 140-cm tubing-switch hourly urine output monitoring device ensures bladder drainage and accurate measurement of urine output, making it ideal for use in intensive care, cardiology, and urology units.

Its connector fits all urinary catheters, eliminating any risk of incompatibility.

Its flat, needle-free sampling port eliminates the risk of needle-stick injuries and allows for the collection of “fresh” urine without disconnecting the catheter or requiring a complete cleaning.
The anti-reflux valve prevents urine backflow, thereby avoiding renal complications.
The cross-shaped valve allows for easy one-handed operation for drainage.

The flexible valve tip allows for easy connection to Infineed short-term bags (COLVA, _X, _XST, _XSTB) for closed-system drainage.

Integrated hook attachment system.

Technical
information

Indications 
Replace the urine output monitoring device every time the urinary catheter is changed to maintain a closed system. Never exceed 1 month. Approximate usage times for the closed system based on the type of catheter used, depending on the catheter material: Silicone-coated latex / Catheterization duration less than 1 week 100% silicone / Catheterization duration 1 week to 1 month Latex with hydrogel coating (internal and external) / Catheterization duration of 1 week to 1 month (Based on supplier recommendations and the catheter's CE class)

Used materials 
Cap: PE Needleless, tube, bag, Dog rest, Drain tube, : PVC Bed Clamp, Bed sheep clamp, Precision bottle, T-Tap: ABS Air Filter: Hydrophobic Polymer Shoelace: Nylon T-Tap: EVA

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : Ism
  • MD notified body : CE2862
  • EU directive/regulation : réglement 2017/745 UE
  • annexe : IX

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Urine collection bags - Part 2: Requirements and test methods

Logistics
information

Transport conditions 

Protected from light and humidity

Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
BAG 1 28 x 48 x 1 0.290 06972992510673
UNIT 1 6972992510673
CASE 20 36 x 65 x 28 5.800 16972992510670

The 140-cm tubing-switch hourly urine output monitoring device ensures bladder drainage and accurate measurement of urine output, making it ideal for use in intensive care, cardiology, and urology units.

Its connector fits all urinary catheters, eliminating any risk of incompatibility.

Its flat, needle-free sampling port eliminates the risk of needle-stick injuries and allows for the collection of “fresh” urine without disconnecting the catheter or requiring a complete cleaning.
The anti-reflux valve prevents urine backflow, thereby avoiding renal complications.
The cross-shaped valve allows for easy one-handed operation for drainage.

The flexible valve tip allows for easy connection to Infineed short-term bags (COLVA, _X, _XST, _XSTB) for closed-system drainage.

Integrated hook attachment system.

Indications 
Replace the urine output monitoring device every time the urinary catheter is changed to maintain a closed system. Never exceed 1 month. Approximate usage times for the closed system based on the type of catheter used, depending on the catheter material: Silicone-coated latex / Catheterization duration less than 1 week 100% silicone / Catheterization duration 1 week to 1 month Latex with hydrogel coating (internal and external) / Catheterization duration of 1 week to 1 month (Based on supplier recommendations and the catheter's CE class)

Used materials 
Cap: PE Needleless, tube, bag, Dog rest, Drain tube, : PVC Bed Clamp, Bed sheep clamp, Precision bottle, T-Tap: ABS Air Filter: Hydrophobic Polymer Shoelace: Nylon T-Tap: EVA

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : Ism
  • MD notified body : CE2862
  • EU directive/regulation : réglement 2017/745 UE
  • annexe : IX

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Urine collection bags - Part 2: Requirements and test methods

Transport conditions 

Protected from light and humidity

Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
BAG 1 28 x 48 x 1 0.290 06972992510673
UNIT 1 6972992510673
CASE 20 36 x 65 x 28 5.800 16972992510670

Associated products

Associated products

Request for technical documentation

  • Didactic formally undertakes not to sell, rent or exchange any personal information. In application of articles 39 and following of the law of January 6, 1978 modified relating to data processing and freedoms (CNIL), you have the right to access, delete and rectify information concerning related to you.