SAFETY SCALPEL SWANN MORTON

  • Sterile Safety Scalpe
  • Available in N°10, 15, 20, 21, 22, 23, 24, 11P
  • Active safety

Description

Swann Morton safety scalpel with stainless steel blade and ABS handle

Technical
information

Indications 
Single-use scalpel for laparoscopic surgery

Used materials 
Blade: SF100 stainless steel (carbon, chrome, silicon sulfur, manganese, phosphorus, nickel) Handle: ABS

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIA
  • MD notified body : 2797
  • EU directive/regulation : Règlement UE
  • annexe : VIII

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Sterilization of medical devices - Requirements for medical devices to be designated "STERILE" - Part 1: Requirements for terminally sterilized medical devices;
  • Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management procee
  • Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals
  • Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems - Amendment 1
  • Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes - Amendment 1
  • Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements

Swann Morton safety scalpel with stainless steel blade and ABS handle

Indications 
Single-use scalpel for laparoscopic surgery

Used materials 
Blade: SF100 stainless steel (carbon, chrome, silicon sulfur, manganese, phosphorus, nickel) Handle: ABS

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIA
  • MD notified body : 2797
  • EU directive/regulation : Règlement UE
  • annexe : VIII

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Sterilization of medical devices - Requirements for medical devices to be designated "STERILE" - Part 1: Requirements for terminally sterilized medical devices;
  • Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management procee
  • Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals
  • Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems - Amendment 1
  • Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes - Amendment 1
  • Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements

Request for technical documentation

  • Didactic formally undertakes not to sell, rent or exchange any personal information. In application of articles 39 and following of the law of January 6, 1978 modified relating to data processing and freedoms (CNIL), you have the right to access, delete and rectify information concerning related to you.